Parameter Name Description
NON-RAID – Each recording le is stored on
only one hard disk. The disk
usage is high, but the data
storage reliability is lower than
that in RAID 5 mode.
– When the number of hard disks is
greater than or equal to 7, the
system automatically uses the
three hard disks with the smallest
slot numbers to form a RAID 1
group, in which one hard disk
functions as the hot spare disk.
Every four of the remaining hard
disks form a RAID 10 group. If the
number of remaining hard disks
is less than 4, the disks do not
form a RAID 10 group.
Step 5 Modify the IP address for the IVS1800.
1. Choose Local
Conguration > Server conguration. Set the service IP
address (internal IP address of the IVS1800), time zone, and time according to
the site requirements.
Figure 5-71
Conguring the server (Single Mode by default)
Set Business IP to XXX.XXX.XXX.XXX, Subnet mask to 255.255.255.0, and Gateway IP
to XXX.XXX.XXX.XXX. The values here are examples. The actual values may vary.
2. Change the PC IP address to an address in the network segment of the new
IVS1800 IP address, enter the IVS1800 IP address in the address box of the
Internet browser, and log in to the OMU portal system.
FusionModule2000-S Smart Modular Data Center
User Manual 5 Power-On Commissioning
Issue 07 (2022-09-30) Copyright © Huawei Technologies Co., Ltd. 236