C
C
W703
W704
W879
W880
W881
W882
W853
W854
W855
W856
W883
W885
W886
W873
W874
W871
W872
W875
W876
W877
W878
W852
W851
W847
W715
W716
W713
W714
W841
W842
W846
W707
W712
W711
7
12
2
2
4
15
16
-X106P:9
-X106S:9
10 10
6
6
8
-X211P:1 -X211S:1
2 2
W77
W78
W81
W82
W71
W72
W73
W74
W83
W85
W86
W79
W80
W75
W76
-X212P:1 -X212S:1
2
2
-X216P:1
-X216S:1
2
2
-X214P:1
-X214S:1
2 2
-X215P:1
-X215S:1
2
2
-X213P:1
-X213S:1
2 2
-X104P:11
W53
12
W54
W55
W56
14
W804
W808
W812
W818
W822
W826
W832
W836
W705
W845
W751
W753
W717
W901
W902
-S1
-S2 -S3
-S6
-B1
-B6
-B4
-B2
-B5
-B3
-B22
-S4
-S5
-X236P:1
-X236S:1
2 2
-X235P:1
-X235S:1
2 2
-X106P:1 -X106S:1
-X106P:11
-X106S:11
W612
W624
-X302P:24
-X302P:12
W611
W623
-X302P:23
-X302P:11
W610
W622
-X302P:22
-X302P:10
W609
W621
-X302P:21
-X302P:09
from 3/C1
W848
W849
W850
W866
W865
W884
14
Red/红色
White/白色
Green/绿色
W752
W718
W754
W719
W755
W720
29
J1
W904
W41
W42
13
21
1
5
7
11
15
16
3
8
9
10
12
14
22
20
23
24
2526
27
19
18
4
17
2
30
31
32
-X104S:11
12
14
15
16
14
4
7
12
8
-X106P:5
-X106S:5
-X104P:13 -X104S:13
-X106P:3 -X106S:3
-X106P:13 -X106S:13
White/白色
Orange/橙色
White/白色
Blue/蓝色
白 橙 白 蓝 白 绿 白 棕
White White White White
Orange Blue Green Brown
白 橙 白 蓝 白 绿 白 棕
White White White White
Orange Blue Green Brown
白 橙白蓝 白 绿
White White White
Orange
Blue
Green
白 橙白蓝 白 绿
White White White
OrangeBlue Green
6
-K1
-K2
14
-A2
-A1
-B21
-X103S:13 -X103P:13
-X104P:5
-X104S:5
-X234P:1
-X234S:1
-X337P:1
-X337S:1
2
2
2
2
2
SPD alarm
防雷器故障告警
3
control relay to condensate pump1
冷凝泵1控制继电器
4 -K2 冷凝泵2控制继电器
5 -S2 冷凝水高液位开关
1 Clogged filter alarm 过滤网压差开关
6
7
8
9
10
11
AC/DC 48V unit alarm
DC48V插框电源故障
12 三通比例阀控制
control chilled water valve
13 回风温度1
Return air temperature sensor 1
14
15
柜外水浸传感器(预留)
Leakage detector ( reserve)
16 烟雾传感器(预留)
Smoke sensor ( reserve)
17 三通比例阀反馈
Rotation position feedback
18
8#风机转速反馈
Fan8 speed feedback
19
-B2
Leaving fluid temperature sensor
出水温度
20
21
-S1
-K1
control relay to condensate pump2
High liquid level switch
-S3 冷凝水低液位开关
low liquid level switch
Fan1-7 speed feedback
1#-7#风机转速反馈
Fan1-fan2 speed control output 1#-2#风机转速控制输出
-S6 远程开/关机(预留)
Remote ON/OFF ( reserve)
-B3
送风温度1
Supply air temperature sensor 1
-B5
-S4
-S5
柜内水浸传感器
Warning pan level sensor
-B22
-B1
Entering fluid temperature sensor
进水温度
22
送风温度2
Supply air temperature sensor 2
-B6
回风温度2
Return air temperature sensor 2
-B4
23
24
-A2
panel
操控板
25
26
温湿度传感器
Temperature & humidity sensor
-B21
group communication
群控通信
27
上位机通信
主控板电源
Controller board power supply
Long-distance computer communication
28
输入电压识别
Voltage jumper ID
-A3
29
电子标签识别板
ESN PCB
-A3
-X6:3
-X104P:4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
13
14
13
-X233P:1
-X233S:1
2
2
6
6
W47
W48
W49 W50
7
7
8
8
-X9:1
-X8:11
-X101P:4
-X104P:3
-X6:4
-X6:2
-X5:2
2
1
1
2
5 6 9 10
1
2
1
2
12345678
-X8:10
246
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
4
1
2
3
7 8
46
4
3
46
- FV1 : C
-X101
-X101 P :12
-X103 P :4
- FV1 : NC
14
14
9
9
10
10
1
2
1
2
1
2
1
2
W51
W52
-X102P:4
-X102P:8
-X102P:12
-X103P:8
-X105P:9
-X105P:10
3 4
3
-X9:2
-X8:5
-X9:3
-X8:5
-X9:4
-X8:5
1
2
30
Fan3-fan4 speed control output 3#-4#风机转速控制输出
31
Fan5-fan6 speed control output 5#-6#风机转速控制输出
Fan7-fan8 speed control output 7#-8#风机转速控制输出
Note:
1、主控板靠近通信口8位拨码开关S1装配时拨码位置要求,
说明
Be sure setting the 8-bit switch of -A1-S1 to
1-8位依次为OFF-OFF-ON-ON-OFF-ON-OFF-ON;
OFF-OFF-ON-ON-OFF-ON-OFF-ON from bit1 to bit8;
2、温湿度传感器B21装配时拨码位置要求,
Be sure setting the 6-bit switch of -B21 to
1-6位依次为OFF-OFF-ON-ON-OFF-ON-OFF-ON;
ON-OFF-ON-OFF-ON-OFF from bit1 to bit6;
-X104P:
-X104S:
-X104P:
-X104S:
1
2
3
4
1
5
4
3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6
1 2 3 4 5 6
Panel
1 2 3 4 5 6
T&H sensor
Controller wiring diagram
Main Board
Long-distance
computer
Main Board
Main
Board
J73
DOWN
J73
UP
J127 J121 J72 J122 J128 J149
J84
J99
J116
J4
J145
J3
J2
J93
J67
J129
J107
J108
J76
J77
J86
J85
J88
J87
J146
J147
J78
J75
J105J106
J104J103
J73(UP)
J73
DOWN
J73
(UP)
J73
DOWN
J69
J94
J70
J134
J83
J74
J130
J152
J80
J114
J113
J112
J111
J110
J109
J6J7
J5
J115
J68
RS485
CAN
CAN
RS485
CAN
J144
CAN J1
Electrical Connection Diagram
Electrical Connection Diagram (Page 4)
NetCol5000-C In Row Cooling Product User Manual