Do you have a question about the Huawei NetCol5000-A035 and is the answer not in the manual?
Model | NetCol5000-A035 |
---|---|
Cooling Capacity | 35 kW |
Refrigerant | R410A |
Noise Level | ≤65 dB(A) |
Power Supply | 380/400/415 V AC, 50/60 Hz |
Dimensions (HxWxD) | 2000 mm x 600 mm x 1000 mm |
General safety guidelines for operating and maintaining the equipment.
Specifies the qualifications and training required for personnel.
Ensures proper grounding and electrical safety precautions.
Requirements for the environment where the equipment is installed.
Safety guidelines for mechanical operations like hoisting and ladders.
Safety precautions related to the cooling system, welding, and pressure.
Explains the naming rule for the NetCol5000-A series products.
Describes the components of the NetCol5000-A system.
Details the appearance and components of the indoor unit.
Specifies operating temperature and humidity requirements.
Provides general parameters and specifications of the product.
Preparation steps and tools needed for installation.
Lists the general tools required for installation.
Lists materials required for installation and optional components.
Details about the R410A refrigerant and its quality checks.
Lists and describes optional pipe components for installation.
Instructions for installing water and drain pipes for humidifiers.
Principles for positioning and layout during installation.
Procedure for unpacking the product.
Procedure for checking the air pressure in the system.
Procedure for removing transport fasteners from components.
Procedure for removing transport fasteners from floats.
Procedure for removing transport fasteners from the compressor.
Flowchart illustrating the indoor unit installation process.
Steps for installing the indoor unit.
Procedure for installing the indoor unit on a base or raised floor.
Procedure for installing the indoor unit directly on the floor.
Procedure for exhausting nitrogen from refrigerant pipes before welding.
Guidelines for connecting refrigerant pipes.
Procedure and considerations for connecting refrigerant pipes.
Instructions for connecting water pipes for humidifier and drain.
Procedure for checking refrigerant pipes for leaks.
Instructions for installing optional cabinet accessories like enclosure frames.
Procedure for installing an enclosure frame to expand depth.
Procedure for installing a top frame to increase height.
Guidelines for connecting power, signal, and communication cables.
Preparations and safety precautions before connecting cables.
Procedure for connecting the power cable to the indoor unit.
Details on connecting various signal cables.
Procedure for connecting the water sensor cable.
Configuration for teamwork networking and monitoring.
Checklist for verifying all connections after installation.
Description of the controller's appearance and indicator status.
Diagram showing the ports on the controller.
Overview of the controller's home screen interface.
Visual representation of the controller's menu structure.
Steps for initial setup and configuration after power-on.
Procedure for performing initial quick settings.
Steps for initial configuration of the system.
Procedure for user login and authentication for security.
Procedure for setting temperature and humidity parameters.
Procedure for setting IP address, subnet mask, and gateway.
Procedure for configuring Modbus communication parameters.
Parameters for configuring teamwork control among multiple units.
Optional settings for configuring alarm reporting and behavior.
Steps for commissioning smart cooling product components.
General guidance for maintaining the smart cooling product.
Procedure to view temperature and humidity curves.
Procedure to query active and historical alarms.
Procedure to query system logs.
Procedure to query device runtime data.
How to check the status of system components.
How to query system parameters via Operating Info or Device Details.
Procedures for changing system parameters.
Procedure to delete historical alarm records.
Procedure for exporting system data like alarms and logs via USB.
Procedure for calibrating temperature and humidity sensors.
Frequently Asked Questions and troubleshooting.
Answers questions about performing quick settings.
Answers questions about changing user passwords.
Answers questions about restoring factory settings.
Troubleshooting for system faults during upgrade mode.
Procedure for manually clearing alarms.
Procedure for changing the SSH access password.
Troubleshooting steps for E-label identification board faults.
Procedure for importing security certificates and keys.
Lists the tools required for commissioning the equipment.
Procedures for vacuumizing and charging refrigerant and oil.
Calculations for determining refrigerant and oil charge amounts.
Procedure for vacuumizing the cooling system.
Procedure for partially charging the refrigerant.
Checks and preparations before powering on for commissioning.
List of checks to perform before powering on the unit.
Procedure for powering on the unit.
Detailed steps for commissioning the system.
Identifies components that require maintenance.
Procedures for regular maintenance tasks.
Lists the tools required for performing maintenance.
Specific maintenance items to be performed monthly.
Specific maintenance items to be performed quarterly.
Reference for system alarms, their causes, and solutions.
General troubleshooting guide for common issues.
Procedures for replacing various system parts.
Procedure for replacing the air filters.
Procedure for replacing the indoor fan.
Procedure for replacing the compressor unit.
Procedure for replacing the high pressure switch.
Procedures for replacing Huawei and Danfoss compressor drives.
Procedure for replacing the Huawei compressor drive.
Procedure for replacing the condensate pump.
Procedure for replacing the humidifier cylinder.
Procedure for replacing the electric heater.