[110] IP Address (Parameter No.140)
No. Name Symbol Unit Input Range
Default factory
setting
140 IP Address IPAD –
0.0.0.0 to
255.255.255.255
192.168.0.1
It is the parameter dedicated for Fieldbus (EtherNet/IP).
[For details, refer to Fieldbus Instruction Manual.]
[111] Subnet Mask (Parameter No.141)
No. Name Symbol Unit Input Range
Default factory
setting
141 Subnet Mask SNMK –
0.0.0.0 to
255.255.255.255
255.255.255.0
It is the parameter dedicated for Fieldbus (EtherNet/IP).
[For details, refer to Fieldbus Instruction Manual.]
[112] Default Gateway (Parameter No.142)
No. Name Symbol Unit Input Range
Default factory
setting
142 Default Gateway DFGW –
0.0.0.0 to
255.255.255.255
0.0.0.0
It is the parameter dedicated for Fieldbus (EtherNet/IP).
[For details, refer to Fieldbus Instruction Manual.]
[113] Overload Level Ratio (Parameter No. 143)
No. Name Symbol Unit Input Range
Default factory
setting
143 Overload Level Ratio OLWL % 50 to 100 100
With the motor thrust increase temperature of when an overload alarm gets generated being
set as 100%, the overload warning (message level) is output when the motor temperature
exceeds the rate set in this parameter.
The judgment would not be made if the value is set to 100%.
[Applied: prevention function]
By setting this parameter, warning output (BALM/OVLM/ALML Signal) notifies you before the
equipment stops by error in case that the motor temperature rises due to load condition
change caused by dry-up of grease or wear-out of components.