1. Specications Check
30
1.2.4 Selection of Leak Current Breaker
A ground fault circuit interrupter needs to be selected carefully considering the purposes of
prevention of fire and protection of human.
Leak current varies depending on the capacity of connected motor, cable length and the
surrounding environment. Measure the leak current at the point where a ground fault circuit
interrupter is to be installed when leakage protection is conducted.
Use the harmonic type (for inverter) for the ground fault circuit interrupter.