EasyManuals Logo

IBM RackSwitch G8000 User Manual

IBM RackSwitch G8000
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
© Copyright IBM Corp. 2011 Chapter 3. Switch Software Management 49
Recovering from a Failed Upgrade
Use the following procedure to recover from a failed software upgrade.
1. Connect a PC to the serial port of the switch.
2. Open a terminal emulator program that supports XModem Download (for
example, HyperTerminal, CRT, PuTTY) and select the following serial port
characteristics:
Speed: 9600 bps
–Data Bits: 8
–Stop Bits: 1
Parity: None
Flow Control: None
3. Boot the switch and access the Boot Management menu by pressing <Shift B>
while the Memory Test is in progress and the dots are being displayed.
4. Select 3 for Xmodem download. When you see the following message,
change the Serial Port characteristics to 115200 bps:
5. Press <Enter> to set the system into download accept mode. When the
readiness meter displays (a series of “C” characters), start XModem on your
terminal emulator.
## Switch baudrate to 115200 bps and press ENTER ...

Table of Contents

Other manuals for IBM RackSwitch G8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RackSwitch G8000 and is the answer not in the manual?

IBM RackSwitch G8000 Specifications

General IconGeneral
BrandIBM
ModelRackSwitch G8000
CategoryNetwork Router
LanguageEnglish

Related product manuals