EasyManuals Logo

IBM RackSwitch G8000 User Manual

IBM RackSwitch G8000
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
50 RackSwitch G8000: Application Guide
6. Select the Boot Image to download. The XModem initiates the file transfer.
When the download is complete, a message similar to the following is
displayed:
7. When you see the following message, change the Serial Port characteristics to
9600 bps:
8. Press the Escape key (<Esc>) to re-display the Boot Management menu.
9. Select 3 to start a new XModem Download. When you see the following
message, change the Serial Port characteristics to 115200 bps:
10. Press <Enter> to continue the download.
yzModem - CRC mode, 62494(SOH)/0(STX)/0(CAN) packets, 6 retries
Extracting images ... Do *NOT* power cycle the switch.
**** VMLINUX ****
Un-Protected 10 sectors
Erasing Flash............. done
Writing to Flash.............done
Protected 10 sectors
**** RAMDISK ****
Un-Protected 44 sectors
Erasing Flash............................................... done
Writing to Flash...............................................done
Protected 44 sectors
**** BOOT CODE ****
Un-Protected 8 sectors
Erasing Flash........... done
Writing to Flash...........done
Protected 8 sectors
## Switch baudrate to 9600 bps and press ESC ...
## Switch baudrate to 115200 bps and press ENTER ...

Table of Contents

Other manuals for IBM RackSwitch G8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RackSwitch G8000 and is the answer not in the manual?

IBM RackSwitch G8000 Specifications

General IconGeneral
BrandIBM
ModelRackSwitch G8000
CategoryNetwork Router
LanguageEnglish

Related product manuals