50 RackSwitch G8000: Application Guide
6. Select the Boot Image to download. The XModem initiates the file transfer.
When the download is complete, a message similar to the following is
displayed:
7. When you see the following message, change the Serial Port characteristics to
9600 bps:
8. Press the Escape key (<Esc>) to re-display the Boot Management menu.
9. Select 3 to start a new XModem Download. When you see the following
message, change the Serial Port characteristics to 115200 bps:
10. Press <Enter> to continue the download.
yzModem - CRC mode, 62494(SOH)/0(STX)/0(CAN) packets, 6 retries
Extracting images ... Do *NOT* power cycle the switch.
**** VMLINUX ****
Un-Protected 10 sectors
Erasing Flash............. done
Writing to Flash.............done
Protected 10 sectors
**** RAMDISK ****
Un-Protected 44 sectors
Erasing Flash............................................... done
Writing to Flash...............................................done
Protected 44 sectors
**** BOOT CODE ****
Un-Protected 8 sectors
Erasing Flash........... done
Writing to Flash...........done
Protected 8 sectors
## Switch baudrate to 9600 bps and press ESC ...
## Switch baudrate to 115200 bps and press ENTER ...