1-10 TS3400 Tape Library Maintenance Information
0088
X calibration error #1.
During X calibration,
CTRG. sensor OFF could
not be detected.
CHK 0088
Cycle the power and try again.
0089
X calibration error #2.
During X calibration,
CTRG. sensor ON could
not be detected.
CHK 0089
008A
X calibration error #3.
During X (DRIVE)
calibration, CTRG. sensor
OFF could not be
detected.
CHK 008A
008B
X calibration error #4.
During X (DRIVE)
calibration, CTRG. sensor
ON could not be detected.
CHK 008B
008F
During X operation, a
cartridge magazine was
removed.
CHK 008F
1. Confirm the magazine is closed.
2. Cycle the power and try again.
3. Replace the Library Control Blade (page 9-8).
4. Replace the Back Board assembly (page 9-37).
5. Replace the TS3400 Tape Library chassis (page 9-44).
0090
Y movement error #1.
During Y movement, an
error occurred in the
target stop position’s
origin sensor detection.
CHK 0090
1. Cycle the power and try again.
2. Replace the Library Control Blade (page 9-8).
3. Replace the Accessor assembly (page 9-23).
4. Replace the Accessor Flat Cable Plate assembly (page 9-28).
5. Replace the Back Board assembly (page 9-37).
6. Replace the TS3400 Tape Library chassis (page 9-44).
0091
Y movement error #2.
During Y movement, the
motor lost sync with
commanded position.
CHK 0091
0092
Y movement error #3.
During initialization, the
motor lost sync with
commanded position.
CHK 0092
1. Cycle the power and try again.
2. Replace the Library Control Blade (page 9-8).
3. Replace the Accessor assembly (page 9-23).
4. Replace the Accessor Flat Cable Plate assembly (page 9-28).
5. Replace the Back Board assembly (page 9-37).
6. Replace the TS3400 Tape Library chassis (page 9-44).
0094
During initialization, the
Y origin position could
not be detected.
CHK 0094
0098
Y calibration error #1.
During Y calibration,
CTRG. sensor OFF could
not be detected.
CHK 0098
Cycle the power and try again.
0099
Y calibration error #2.
During Y calibration,
CTRG. sensor ON could
not be detected.
CHK 0099
Table 1-1. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required