218-904-000 Brocade:ExternalEthLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check or replace SFP/cable.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-905-000 Brocade:SerdesEthLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-904-000 • 218-905-000
Appendix B. DSA diagnostic test results 351