Replacing 2.5-inch and 1.8-inch hot-swap drives
This information provides instructions on how to replace 2.5-inch and 1.8-inch
hot-swap drives.
About this task
The following notes describe the type of drives that the server supports and other
information that you must consider when you install a drive. For a list of
supported drives, see http://www.ibm.com/servers/eserver/serverproven/
compat/us/.
v Locate the documentation that comes with the drive and follow those
instructions in addition to the instructions in this chapter.
v Make sure that you have all the cables and other equipment that are specified in
the documentation that comes with the drive.
v The server can support up to 16 2.5-inch drives, up to 32 1.8-inch drives, or a
combination of both 2.5-inch and 1.8-inch hot-swap drives, using the supported
SAS\SATA backplane configurations. The server supports 2.5-inch hot-swap SAS
or hot-swap SATA hard disk drives, 2.5-inch hot-swap solid state drive, or
1.8-inch hot-swap solid state drives (see “Supported SAS/SATA drive backplane
configurations” on page 56 for more information).
v You can mix 2.5-inch hot-swap SAS and SATA hard disk drives, 2.5-inch
hot-swap solid state drive, and 1.8-inch hot-swap solid state drives in the same
server as long as they are not on the same array.
v When upgrading drive backplane configurations, all 1.8-inch SSD drive
backplanes must be installed to the right of all 2.5-inch HDD or 2.5-inch SSD
drive backplanes. All 2.5-inch backplanes installs to the left of all 1.8-inch
backplanes. See “Drive IDs” on page 54 for drive ID assignment information and
“Supported SAS/SATA drive backplane configurations” on page 56 for
information about the combination of supported drive backplane configurations.
v The electromagnetic interference (EMI) integrity and cooling of the server are
protected by having all bays and PCI and PCI Express slots covered or occupied.
When you install a drive, save the EMC shield and filler panel from the bay in
the event that you later remove the device.
v For a complete list of supported optional devices for the server, see
http://www.ibm.com/servers/eserver/serverproven/compat/us/.
To install a hot-swap drive, complete the following steps:
Procedure
1. Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 35.
2. Touch the static-protective package that contains the drive to any unpainted
metal surface on the server; then, remove the drive from the package and place
it on a static-protective surface.
3. Install a 2.5-inch hot-swap drive:
a. Make sure that the drive-tray handle is in the open (unlocked) position.
b. Align the drive assembly with the guide rails in the bay.
238 System x3750 M4 Types 8722 and 8733: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3750 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3750 M4 and is the answer not in the manual?

IBM System x3750 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3750 M4
CategoryServer
LanguageEnglish

Related product manuals