215-801-000 Optical Drive Test Aborted
Explanation: Optical Drive Test Aborted. Unable to communicate with driver.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the DSA Diagnostic code is at the latest level.
2. Run the test again.
3. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
4. Run the test again.
5. Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
6. Run the test again.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
215-802-000 Optical Drive Test Aborted
Explanation: Optical Drive Test Aborted. A read error was encountered.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.
2. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
215-801-000 215-802-000
452
System x3750 M4 Types 8722 and 8733: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3750 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3750 M4 and is the answer not in the manual?

IBM System x3750 M4 Specifications

General IconGeneral
Form FactorRack-mountable
Expansion SlotsUp to 7 PCIe 3.0 slots
Rack Height2U
Product TypeServer
Rack-mountableYes
MemoryUp to 768 GB
RAID SupportRAID 0, 1, 5, 10
Network InterfaceIntegrated quad-port Gigabit Ethernet
Power SupplyDual redundant hot-swap power supplies
Operating SystemWindows Server, Linux, VMware

Related product manuals