10
OTHER FUNCTIONS
10-22
Remote jack (CI-V) information (Continued)
VOX gain setting
Command: 14 16
OFF 1 2 3 4
0000 ~ 0022 0023 ~ 0046 0047 ~ 0069 0070 ~ 0092 0093 ~ 0115
5 6 7 8 9
0016 ~ 0139 0140 ~ 0162 0163 ~ 0185 0186 ~ 0208 0209 ~ 0232
10
0233 ~ 0255
Repeater tone/tone squelch frequency setting
Command: 1B 00, 1B 01
q* ew
0 0
X X X X
Fixed: 0
Fixed: 0
100 Hz digit
10 Hz digit
1 Hz digit
0.1 Hz digit
*Not necessary when setting a frequency.
L See page 9-16 for the tone frequency list.
DTCS code and polarity setting
Command: 1B 02
X X 0 X X X
q w e
0 (fixed)
First digit: 0 ~ 7
Second digit: 0 ~ 7
Third digit: 0 ~ 7
Receive polarity: 0: Normal
1: Reverse
Transmit polarity: 0: Normal
1: Reverse
L See page 9-16 for the DTCS code list.
Digital code squelch setting
Command: 1B 07
X X
q
First digit: 0 ~ 9
Second digit: 0 ~ 9
DV MY call sign setting
Command: 1F 00
Set your own call sign and note of up to 12 characters.
X X X X X X X X X X X X
o ~ !2q ~ i
• • •
q ~ i: Your own call sign setting (8 characters)
o ~ !2: Note setting (4 characters)
DV TX call signs setting (24 characters)
Command: 1F 01
Set “UR,” “R1” and “R2” call signs of 8 characters
(xed).
X X
• • •
X X X X X X X X X X
• • •
!7 ~ @4o ~ !6q ~ i
• • •
q ~ i: UR (Destination) call sign setting (8
characters)
o ~ !6: R1 (Access/Area repeater) call sign setting (8
characters)
!7 ~ @4: R2 (Link/Gateway repeater) call sign setting
(8 characters)
Character’s code of the call sign
Character ASCII code
0 ~ 9 30 ~ 39
A ~ Z 41 ~ 5A
(Space) 20
/ 2F
DV TX message setting
Command: 1F 02
Set the transmit message of up to 20 characters.
“FF” stops sending or reading messages.
Character ASCII code Character ASCII code
A ~ Z 41 ~ 5A a ~ z 61 ~ 7A
0 ~ 9 30 ~ 39 Space 20
! 21 # 23
$ 24 % 25
& 26 \ 5C
? 3F " 22
’ 27 ` 60
^ 5E + 2B
– 2D
M
2A
/ 2F . 2E
, 2C : 3A
; 3B = 3D
< 3C > 3E
( 28 ) 29
[ 5B ] 5D
{ 7B } 7D
¦ 7C _ 5F
¯ 7E @ 40