EasyManuals Logo

Inficon Cygnus 2 User Manual

Inficon Cygnus 2
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
1 - 8
Cygnus 2 Operating Manual
1.4.3.4 Material Parameters
6 Materials can be specified and given unique names (15 character max.).
Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.100 to 99.999 g/cc
Z-ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.100 to 15.000
Master Tooling . . . . . . . . . . . . . . . . . . . . . . . 1.0 to 999.9%
Control Loop types . . . . . . . . . . . . . . . . . . . . Non-PID, PI, PID
Process Gain . . . . . . . . . . . . . . . . . . . . . . . . 0.01 to 999.99 Ã…/s/%Power
Time Constant . . . . . . . . . . . . . . . . . . . . . . . 0.010 to 9999.99 s
Dead Time . . . . . . . . . . . . . . . . . . . . . . . . . . 0.010 to 9999.99 s
Maximum Source Power . . . . . . . . . . . . . . . 0.01 to 99.99%
Minimum Source Power . . . . . . . . . . . . . . . . 0.00 to 99.98%
Maximum Power Option . . . . . . . . . . . . . . . . Continue, Post-Dep(osition), Stop All,
Stop Mat(erial)—can be selected for
each Material individually
Power Ramps. . . . . . . . . . . . . . . . . . . . . . . . 3 per Material
Power Level . . . . . . . . . . . . . . . . . . . . . . 0.00 to 99.99%
Rise Time . . . . . . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s
Soak Time. . . . . . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s
Auto Soak 2 . . . . . . . . . . . . . . . . . . . . . . . . . Yes / No
Deposit After Pre-Deposit. . . . . . . . . . . . . . . Yes / No
Yes = go to Deposit
No = go to Non-Deposit Rate Control
(Control) Delay Option . . . . . . . . . . . . . . . . . None, Shutter, Control, Both
Control Delay Time. . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s
Shutter Delay Accur(acy) . . . . . . . . . . . . . . . 1 to 99%
Feed Power . . . . . . . . . . . . . . . . . . . . . . . . . 0.00 to 99.99%
Feed Ramp Time . . . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s
Feed Time . . . . . . . . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s
Idle Ramp . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Source
Idle Power. . . . . . . . . . . . . . . . . . . . . . . . 0.00 to 99.99%
Idle Ramp Time . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s
Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.000 to 999.9 Ã…/s