Mounting and Positioning Holes
There are two positioning holes located on the mounting bracket as shown below.
Use 2 M2 screws with a minimum engagement of 4 mm / 0.16 in to mount the
imager + ED40 into your design.
EA20X + ED40 Mounting and Positioning Holes
Positioning holes (2 places)
diameter 2 mm/0.08 in,
depth 2.5 mm/0.10 in
Hole for M2 screw (2 places)
min. engagement 4 mm/0.16 in
30 mm
1.18 in
7.95 mm
0.31 in
12.95 mm
0.51 in
Note: The EA20X can also be used unmounted with the ED40 decode board.
The ribbon cable should be 50.8 cm (2 in.) in length with a maximum of 10.16
cm (4 in.). See “Imager Ribbon Cable Connecting to ED40” on page 95 for
more information.