5.3.2.2 BRIB Installation
Before installation of the BRIB, set the Mode, Terminating Resistor, and Power Feed Switches
for each BRIB Line. Note that the BRIB cannot simultaneously support both the T and S mode,
all ports on the BRIB must be set in the same mode, T or S.
The BRIB board can be installed in any universal slot of any KSU; the 1st slot of the BKSU is
for the MPB only.
Assure Power is OFF
Slide the BRIB in the guide rails of the desired slot.
Tighten thumbscrews to hold the board firmly in place.
5.3.2.3 BRIB Wiring
A separate RJ45 connector is provided for each BRI line supported by the BRIB. Referring to
the pin-out chart and Figure 5.3.2.3 1 below,
Wire the TX and RX pins of each RJ-45 connector to the BRI digital line termination
point using UTP cable.
Tag or number wiring for maintenance.