Chapter 9 ERROR SCREENS
ERROR SCREENS
ERROR ID NOS. 105 – 116
ID NO. TITLE TEXT
105 INITIALIZATION FAILED MAKE MEMORY INITIALIZATION
106 BATTERY IS FAULT
BATTERY SWITCH IS OFF OR NO MORE
BATTERY
107
TOUCH PANEL ADJUSTMENT IS NOT
COMPLETED YET
SET UP WITH (TOUCH PANEL) MODE
108
CLOCK SETTING IS NOT COMPLETED
YET
SET UP WITH (CLOCL MODE)
109
PRINTER 1 INITIALIZATION WAS NOT
DONE YET
INITIALIZE PRINTER 1
110
MACHINE SETTING IS NOT
COMPLETED
SET UP WITH (MACHINE SELECTION) MODE
111
THE DISPLAY CONFIREMATION IS
NOT COMPLETED.
PLEASE SET IT ON [DISPLAY CONFIRMATION]
SCREEN OF THE ADJUSTMENT MODE.
112
THE CONFIRMATION OF THE KEY
OPERATION IS NOT COMPLETED.
PLEASE SET IT ON [KEY] SCREEN OF THE
ADJUSTMENT MODE.
113 PRINTER 2 ERROR
PLEASE SET IT ON [COMMUNICATION CHECK]
SCREEN OF THE ADJUSTMENT MODE.
114
THE DATA COMPOSTION IS
DIFFERENNT.
PLEASE INITIALIZE THE MEMORY.
116
THE COUNTRY HAS NOT BEEN
SELECTED.
PLEASE SELECT THE COUNTRY.
ERROR ID NOS. 202 – 295
ID NO. TITLE TEXT
202 PLU MASTER IS NOT PROGRAMMED
PLU No. [*] IS NOT PROGRAMMED.
CHECK PLU No.
203
POSP MASTER IS NOT
PROGRAMMED
POP No. [*] IS NOT PROGRAMMED.
DLETE IT?
204
ORIGIN MASTER IS NOT
PROGRAMMED
COUNTRY OF ORIGIN No. [*] IS NOT
PROGRAMMED
DELETE IT?
205
PRIMARY MATERIAL MASTER IS NOT
PROGRAMMED
MATERIAL No. [*] IS NOT PROGRAMMED
DELETE IT?
206
STORAGE CONDISTION MASTER IS
NOT PROGRAMMED
PRESERVATION WAY No. [*] IS NOT
PROGRAMMED
DELETE IT?
207
TEMPERATURE MASTER IS NOT
PROGRAMMED
TEMPERATURE No. [*] IS NOT PROGRAMMED
DELETE IT?
212 FREE1 MASTER ISN'T REGISTERED
FREE1 No. [*] ISN'T PROGRAMMED.
DELETE IT?
9
UNI-7 Service Manual 9-1