Error Messages
Error
Code
Error Message Description
224 Front panel timeout The serial port connection be-
tween the front panel and the
control board has timed out.
225 Front Crc Check error The CRC check of the serial
port between the front panel
and the control board is
incorrect.
226 Front Cmd Error The serial port command be-
tween the front panel and the
control board is incorrectly
used.
401 CAL switch prevents
calibration
Calibration is disabled due to
the status setting of the calibra-
tion switch.
402 CAL password is incorrect The calibration password is
incorrect.
403 CAL not enabled Calibration is not enabled.
404 Computed readback cal con-
stants are incorrect
An error occurred in reading
the calibration data.
405 Computed programming cal
constants are incorrect
An error occurred in calculating
the calibration data.
406 Incorrect sequence of calibra-
tion commands
The execution order of the cali-
bration commands is incorrect.
407 CV or CC status is incorrect for
this command
The CC or CV status of this
command is incorrect.
408 Output mode switch must be in
NORMAL position
The switch for the output mode
must be NORMAL.
600 Lists inconsistent [lists have
different list lengths]
The lists are inconsistent, such
as a different list length.
601 Too many sweep points There are too many sweep
points.
602 Command only applies to
RS232 interface
This command only applies to
the RS232 interface.
603 FETCH of data that was not
acquired
The data related to the FETCH
command is not acquired.
Copyright © Itech Electronic Co., Ltd.
185