Chapter 3 Ethernet Testing
Initializing the link for Ethernet testing
HST-3000 Ethernet Testing Users Guide
49
If you selected 10/100/1G application, proceed to
step 4.
If you selected an optical 1G or 100M application,
proceed to step 5.
4 If you selected 10/100/1G application, specify the
following settings:
Setting Parameters Applicable
Auto Neg On
Off
Always
NOTE:
If you turn auto-negoti-
ation on, flow control is
also turned on auto-
matically, and the Flow
Control setting does
not appear on the
menu.
Flow Control On
Off
If Auto Neg value is Off
Speed
(Mbps)
10
100
1000
10, 100 Always
1000, If Auto Neg
value is On
Duplex Half
Full
Always
Pause
Quanta
Enter a
pause
quanta
ranging
from 0 to
65535.
Always