3-4 
 
3.1.1 Power ON and Date/Time Setting 
 
 
 
●  Execute  to  turn  on  the  power supply  again  after  thirty  seconds or 
more have passed since the power supply was intercepted.   
●The current meter might power off or malfunction when the ship 
power supply failure while the current meter is working. At that time, 
please turn on the power supply again. 
 
 
 
 
1  Confirm the ship power supply ON. 
2  Push [PWR] key. 
The power supply of the device enters, and normal screen (*1) is displayed.   
It transmits automatically at the same time as displaying the screen, and the measurement begins. 
3  Set the date and time. (*2) 
* When GPS is connected, this operation is unnecessary because it is set by the automatic 
operation. 
1) Push [MENU] key, the menu is displayed. 
2) Select   Time Setting  ≫  by  ▼▲  key. Then, open the sub-menu “Time Setting” by pushing 
[ENT] key. 
3) According to menu items, enter the present Year/Month/Date/Hour/Minute/Second by numeric 
ke y.  
Ex.) Setting of     Month: In case of October, "10" is input by numeric key, [ENT] key is pushed, 
and it fixes. 
4) After inputting Year/Month/Date/Hour/Minute/Second, finally select the item of “   Setting 
Execute” by  ▼▲  key and   key. Then, push [ENT] key, and it fixes. 
5) The menu is ended pushing the [MENU] key again. 
*Set "Date and Time" at that time when you turn on the power supply. 
 
3.1.2 Display Selecting 
 
 
 
The display is selected with the screen selection key to the keyboard. 
1) [CURR] key:    Current screen (*3) is displayed. 
2) [SHIP] key:  Ship speed screen (*4) is displayed. 
3) [PLOT] key:  Track screen (*5) (current vector on the ship track) is displayed. 
4) [GRAPH] key  Graph screen (*6) (passage graphs of the current, ship speed, and depth, etc.) is 
displayed. 
5) [FISH] key  Fish  finder  screen (*7) (reflection in the sea echo such as shoals of fish) is 
displayed.   
*Ship speed and the current cannot display the measurement on the fish finder 
screen. 
6) [PROFILE] key  Profile screen (*8) (measurement graph of the multilayer current) is displayed.   
 
 
 
 
*1  Normal Screen:  When the factory is shipped, "current 1  screen" is displayed. Next time, the screen displayed at the end 
(power supply determination) is displayed. 
*2  Setting Date /Time: In case of not setting he  Date/Time,  the misdate time  is saved  when the measured current data is 
memorizing saved. 
*3  Current Screen:    Refer to 2.2.1 “Tidal Current Display”.  *4  Ship Screen:    Refer to 2.2.2 “Ship Speed Display”. 
*5  Plot Screen:    Refer to 2.2.3 “Track Plot Display”.  *6  Graph Screen:    Refer to 2.2.4 “Graph Display”. 
*7  Fish Screen:    Refer to 2.2.5 “Fish Finder Display”.  *8  Profile Screen  Refer to 2.2.6 “Tidal Profile Display” 
 
 
 
▲
▼
▼
▼