4-13
4
4.1.19 BT WT Average time 3: Short/2/3/4/5/6/7/8/9/Long
Function It is a menu for servicemen.
Use the 3 position usually.
Operation Standard Menu: [MENU] key/Menu screen/ Measure setting/[ENT] key
/BT Ave. Processing time3: Short/2/3/4/5/6/7/8/9/Long
/WT Ave. Processing time3: Short/2/3/4/5/6/7/8/9/Long
About BTWT Average time 3
It is a setting similar to "BTWTTide Average time1".
Although tracking performance is as quick as the numerical value of a setting
being small (or short) and stability becomes high in the numerical value of a
setting being large (or long). However, since other calculation items and a result
have correlation, the expected setting result is not necessarily obtained.
4.1.20 Tide Response Time 1: Short/2/3/4/5/6/7/8/9/Long
Function It is a menu for servicemen.
Use the 6 position usually.
Operation Standard Menu: [MENU] key/Menu screen/ Measure setting/[ENT] key
/Tide Response time 1: Short/2/3/4/5/6/7/8/9/Long
About Tide Response time 1
It is a setting similar to "BTWTTide Average time1".
Although tracking performance is as quick as the numerical value of a setting
being small (or short) and stability becomes high in the numerical value of a
setting being large (or long). However, since other calculation items and a result
have correlation, the expected setting result is not necessarily obtained.
4.1.21 Tide Response Time 2: -3/-2/-1/0/+1/+2/+3/+4
Function It is a menu for servicemen.
Use the 0 position usually.
Operation Standard Menu: [MENU] key/Menu screen/ Measurement setting/[ENT] key
/Tide Response time2: -3/-2/-1/0/+1/+2/+3/+4
About Tide Response time 2
Tracking performance immediately after the start of current calculation is mainly setting.
Tracking performance may be made quick when the bottom of the sea depth measures
a current at the place which becomes deep suddenly.
Tracking performance becomes quick, so that a numerical value is small, and tracking
performance becomes slow, so that a numerical value is large.
If tracking performance is too quick, in the state where beginning displays in a current
value, an actual current and display do not suit in many cases.
When the current at the time of a display start is not stabilized, it sets to a large value.