4-15
4.1.24 Filter Setting 3:G0/G1/G2/G3/G4/H0/H1/H2/H3/H4
Function It is a menu for servicemen.
Use the G1 position usually.
Operation Standard Menu: [MENU] key/Menu screen/ Measure setting≫/[ENT] key
/ Filter Setting 3: G0/G1/G2/G3/G4/H0/H1/H2/H3/H4
About Filter Setting 3
It is a setting item which functions on the operation of a current.
The action which converges a current value to 0 becomes large, so that a
numerical value is large.
Except for the special case, it is used by 1 position.
The variation in the BT ship speed used as a standard is very large, and when a
current value does not approach a true value, it is set as H position.
The function which removes the variation in BT ship speed works, and it can be
expected that tracking (convergence) will become quick. However, since the
fluctuation of the truth of BT ship speed may also be removed, in turning
constantly especially, an actual current value and indicated value are not in match
in many cases.
* Filter Setting 4 is a menu for servicemen.
4.1.25 Filter Setting 4:K0/K1/K2/K3/K4
Function It is a menu for servicemen.
To adjust the threshold to stop the calculation by detecting the change of ship speed and heading.
Use the K3 position usually.
Operation
MENU MEASURE SETTING FILTER SETTING 4 = K0 / K1 / K2 / K3 / K4
About Filter Setting 4
0~4:
To adjust the threshold to stop the calculation by detecting the change of ship speed and heading.
The larger the number, to abort the calculation with a little change. ,
You can expect an effect to reduce the error of the power flow calculation.
But There is a negative effect.
Responsibility is slow, Time to discontinue calculation becomes longer
Use the K3 position usually.
If you want to set the response-oriented (listed separately), will be used in 1.
* Standard setting is current measurement operation of the stability-oriented.
When the configuration changes to the stability-oriented → response emphasis on,
Please refer to the reference set value 7-3) section.