Figure 25: DC Power Supply Faceplate in ACX5000 Routers
5—1— ESD grounding pointFeed B input terminals
6—2— Fault LEDFeed A input terminals
7—3— Output LEDTerminal block
8—4— Input LEDEjector lever
To avoid electrical injury, carefully follow instructions in “Installing a Power Supply in an
ACX5000Router” onpage 137 and “Removing a PowerSupply from an ACX5000Router”
on page 138.
Table 19 on page 41 shows the different power supplies and their direction of airflow.
Table 19: Airflow Direction in ACX5000 DC Power Supplies
Color of Power
Supply HandleDirection of AirflowProduct NumberWattageRouter Model
Juniper GoldPort-to-FRUJPSU-650W-DC-AFO650 WACX5048
JPSU-850W-DC-AFO850 WACX5096
Related
Documentation
• DC Power Supply LEDs on an ACX5000 Router on page 31
• DC Power Specifications for an ACX5000 Router on page 55
• Connecting DC Power to an ACX5000 Router on page 116
• Management Panel of an ACX5000 Router on page 17
• Field-Replaceable Units in an ACX5000 Router on page 5
• Prevention of Electrostatic Discharge Damage
41Copyright © 2015, Juniper Networks, Inc.