Maintain ambient airow for normal operaon. If the airow is blocked or restricted, or if the intake
air is too warm, the device might overheat.
The following table lists the environmental specicaons for the SRX1600:
Table 24: Environmental Specicaons for SRX1600
Descripon Value
Operang temperature 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature -40 °C to 70 °C (-40 °F to 158 °F)
Relave humidity Normal operaon ensured in relave humidity range of 5% through 90%, non-
condensing
Altude 6000 .
Clearance Requirements for Hardware Maintenance of the SRX1600
When planning the site for installing the SRX1600, ensure that there is sucient space around the
installed chassis.
For the operang temperature of the SRX1600 to be opmal, the airow around the chassis must be
unrestricted.
For service personnel to remove and to install hardware components, and to accommodate the
interface and power cable bend radius, there must be adequate space at the front and rear of the
appliance. Allow at least 24 in. (61 cm) of space both at the front and the rear of the appliance.
If you are mounng the appliance in a rack with other equipment, or if you are placing it on the
desktop near other equipment, ensure that the exhaust from other equipment does not blow into the
intake vents of the chassis.