NOTE: For more informaon about alarms, see the Junos OS Monitoring and Troubleshoong for
Security Devices Guide.
Troubleshoong the Power System on the SRX1600
The LEDs on the rewall enable you to determine the performance and operaon of the power system.
The PWR LED located on the front panel of the rewall, as described in "Chassis Status LEDs" on page
15 , indicates the dierent status sengs of the power system.
Table 30: PWR LED Descripon
LED Status LED State Meaning Possible Cause and Correcve Acon
Green On The rewall is receiving
power, and all the AC or
DC power supply units
(PSUs) are working
properly.
The power system is normal and no
acon is required.
Red On One or more PSUs have
failed.
If you cannot determine the cause of the
problem or need addional assistance:
Open a support case using the
Service Request Manager link at
hps://www.juniper.net/support/.
Call 1-888-314-JTAC (if you're within
the United States) or
1-408-745-9500 (if you're outside
the United States).
Blinking green On The rewall, which is in
the bootup phase before
Junos OS inializaon, is
receiving power.
The power system is normal and no
acon is required.