Roune Maintenance Procedures for the SRX1600
To maintain opmum performance of the device, you must regularly perform the following prevenve
maintenance procedures:
Inspect the installaon site for moisture, loose wires or cables, and excessive dust.
Ensure unobstructed airow around the device and into the air intake vents.
Check the status LEDs on the front panel of the device.
SRX1600 Cooling System Maintenance
SUMMARY
Maintaining the SRX1600 includes removing and
installing the fans.
IN THIS SECTION
Remove the Fan Module from the
SRX1600 | 72
Install the Fan Module in the SRX1600 | 72
The SRX1600 has three independent, eld-replaceable fans at the rear of the chassis.
Each fan module is a hot-removable and hot-insertable eld-replaceable unit (FRU). You can remove and
replace the fan module without turning o power to the appliance or disrupng its funcons.
Before you replace a fan module:
Ensure that you understand how to prevent electrostac discharge (ESD) damage.
Ensure that you have the following parts and tools:
An ESD grounding strap
An anstac bag or an anstac mat
A replacement fan module
(Oponal) A Phillips (+) screwdriver, number 1 or 2, for the capve screws