Connect the SRX1600 to Power
SUMMARY
Connecng power to the SRX1600 involves
numerous steps and safety precauons to prevent
equipment damage and personal injury.
IN THIS SECTION
Connect Earth Ground to the SRX1600 | 55
Connect AC Power to the SRX1600 | 57
Connect DC Power to the SRX1600 | 59
Power O the SRX1600 | 61
NOTE: To meet the safety and electromagnec interference (EMI) requirements and to ensure
proper operaon, you must connect the SRX1600 to an earth ground before you connect it to
power.
Connect Earth Ground to the SRX1600
NOTE: Before you connect an earth ground to the protecve earthing terminal of the SRX1600,
ensure that a licensed electrician aaches an appropriate grounding terminal to the grounding
cable you supply. Using a grounding cable with an incorrectly aached terminal can damage the
device.
Before connecng the device to an earth ground, ensure that you have the following parts and tools:
• An electrostac discharge (ESD) grounding strap.
• 2-hole protecve earthing terminal.
• Grounding cable for your device—The grounding cable must be 6 AWG (4.11 mm²) stranded wire and
rated 90 °C or per local electrical code.
• Grounding 2-hole terminal for your grounding cable—This aaches to the chassis grounding point
located on the rear of the device.
• A Phillips screwdriver to ghten the screw.
55