- 14
Observe the following when towing the ma-
chine:
1 Release parking brake.
2 Open the bypass valve on the hy-
drostat.
The emergency brake is locked automati-
cally when the motor is shut off. To release
the emergency brake, either start the motor
and then release the brake or manually re-
lease the brake.
Manually release the emergency brake:
Loosen the nut as per the illustration
below. The nut is located on the right
side of the machine, underneath the
rear of the machine.
Nut to unlock the emergency brake
Loosen nut 1 and 2 to open the bypass
hydrostat.
Bypass valve hydrostat
Troubleshooting
Faults with display
Display Cause Remedy By whom
Warning lamp for
motor temperature
lights up
Engine is overheated Set the engine speed to idle.
Clean the radiator (see "Care and Maintenance).
Run the engine in idle until the warning lamp turns
off.
Check the level of cooling liquid in the engine.
If the warning lamp does not turn off within 5 min-
utes, shut off the engine and contact Customer Ser-
vice.
Operator
Warning lamp for hy-
draulic oil tempera-
ture
Hydraulic oil overheated
Warning lamp for
battery lights up
Battery is not being charged Call Customer Service. Operator
Faults without display
Fault Remedy
Appliance cannot be started Turn on the main switch.
Bring the direction selector switch into the neutral position.
Charging or replacing battery
Fill in fuel, deaerate the fuel system
Clean or replace fuel filter
Check fuel pipes, connections and joints and maintain them if required
Contact the authorised customer service.
Engine is running erratically Clean or replace air filter
Check fuel pipes, connections and joints and maintain them if required
Contact the authorised customer service.
Engine is running but machine is
only moving slowly or is not moving
at all
Release parking brake
Check level of hydraulic fuel
Contact the authorised customer service.
Operation problems with hydraulic
movement parts
Contact the authorised customer service.
Towing
32 EN