N
Noise I-5
Noise and safety shields 2-8
Noise and source impedance I-5
noisy readings I-7
NPLC Menu 4-6
O
Offset voltage calibration 15-7
operating at a higher speed 13-2
Operation
consideration 4-10
event status 10-12
Operation keys 1-7
Optional command words 1-19
Options and accessories 1-4
Output queue 10-18
Output trigger specifications 7-12
Output triggers 7-7
Overview of this manual 1-2
P
Package content 1-4
Parity, RS-232 9-17
peak-to-peak 6-7
Performance considerations 2-2
Performance verification 15-1
Phone number 1-3
Photodiode characterization prior to dicing I-22
Piezoelectric and stored charge effects C-3
PIN photo diode leakage I-24
PKPK 6-7
polling sequence D-12
Pomona 1269 15-4
POWER 1-7
Power module 1-10
Power-up 1-12
Power-up sequence 1-14
Primary address 9-7
Procedure 16-6
Program Message Terminator (PMT) 9-15
Program messages 9-13
Q
Query commands 1-19, 9-12
Questionable event status 10-15
Queues 10-18
R
Rack mount kits 1-5
Range D-6
and values 4-5
keys 1-8
symbols for rel values 5-3
Units, Digits, Rate, and Filters 4-1
range change transients I-12
Rate 1-8, 4-5
Key 4-6
Reading limits for 20µA to 20mA ranges 15-8
Reading limits for 2nA to 2µA ranges 15-9
Reading Mode D-2
Rear panel 1-9
Rear panel summary 1-8
RECALL 1-8
Recall 6-3
Recommended test equipment 15-3
Registers
Bit descriptions 10-10
Condition 10-15
Enable 10-4, 10-5
Event 10-16
Reading 10-6
reinstate the previous Rel 5-2
REL 1-7, 1-8, 5-2
Relative, mX+b, m/X+b (Reciprocal), and Log
5-1
REM 1-8
Remote calibration H-1
Remote setup operation 1-16
REN (remote enable) 9-7
Response 9-15
Message Terminator (RMT) 9-16
time 4-10
restore setup 1-15
Routine maintenance 17-1
RS-232 1-10
connections 9-18
RS-232 interface 9-2, 9-3, 9-16
RS-232 settings 9-16

Table of Contents

Other manuals for Keithley 6485

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 6485 and is the answer not in the manual?

Keithley 6485 Specifications

General IconGeneral
ModelKeithley 6485
CategoryPicoammeter
Input Impedance>10^14 Ohms
Voltage Burden<200µV
Accuracy0.4% of reading
Voltage Source RangeNot Applicable
Voltage Source ResolutionNot Applicable
Voltage Source AccuracyNot Applicable
InterfaceIEEE-488
Power Requirements100V to 240V AC, 50/60Hz
Dimensions89 mm high x 214 mm wide x 369 mm deep (3.5 in x 8.4 in x 14.5 in)