Keysight Technologies N9040B UXA Signal Analyzer Service Guide 119
Instrument Messages
Condition Messages
135 1 No Result; Meas invalid with
I/Q inputs
E The current measurement does not
support I/Q input; switch to the RF or
another input or select a different
measurement
137 2 unused
139 3 Uncalibrated Summary status bit
only
This bit is the summary bit for the
STATus:QUEStionable:INTegrity:UNCali
brated sub-register.
141 4 Input Overload W
141 4 Input Overload;ADC over
range
W The signal at the input to the IF section
is too high. You should increase the
attenuation or lower the signal level.
141 4 Input Overload;I/Q ADC over
range
W The I or Q input exceeds the ADC upper
limit.
141 4 Input Overload;I/Q Voltage
over range
W The input voltage on the I or Q channel
exceeds the channel limit. In differential
mode the over voltage may occur
without causing an ADC overload, for
example, if I is at +5.01 V and I-bar is at
+5.0 the ADC will be in range but both I
and I-bar will exceed the voltage limit.
143 5 unused
145 6 unused
147 7 Insufficient Data E
147 7 Insufficient Data; Incr.
Demod Time
E There is insufficient acquisition data to
provide accurate metrics. You should
increase the Demod Time to acquire
enough data.
147 7 Insufficient Data; frequency
list empty
E A measurement was attempted with List
frequency mode or a SCPI query of the
frequency list table was made and the
frequency list table is empty.
147 7 Insufficient Data; ENR table
empty
E A measurement was attempted or a
SCPI query of an ENR table was made
and there were no entries in the relevant
ENR table (Common, Meas or Cal).
147 7 Insufficient Data; Loss
table empty
E A measurement is attempted or a SCPI
query of a before or after loss table is
made and there are no entries in the
relevant loss table
Err# Bit in
status
register
Message Error or
Warning
More Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight N9040B Option 508 and is the answer not in the manual?

Keysight N9040B Option 508 Specifications

General IconGeneral
BrandKeysight
ModelN9040B Option 508
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals