60 PWR-01
Basic Features CONFIG Settings
CF09 (OFF.D) Output-off delay setting
You can set the delay from when the OUTPUT key is pressed to when the output actually
turns off (p.38).
CF10 (
E.CC
) CC control using an external voltage/ external resistance
Enables or disables constant current control using an external voltage or external resistance
(p.92).
CF11 (
E.CV
) CV control using an external voltage/ external resistance
Enables or disables constant voltage control using an external voltage or external resistance
(p.90).
CF12 (E.RNG) CV/ CC control range
Sets the range for performing constant current or constant voltage control using an external
voltage or external resistance (p.90, p.92).
Reference voltage for external control (J1-3 REFOUT) is also set to 5.25 V (CF12: LO) or
10.5 V (CF12: HI) according to the range setting.
CF13 (M.RNG) Voltage/ Current monitor output range
Sets the voltage range when monitoring voltage or current (p.98). You can also set this
parameter when the PWR-01 is being used as a slave unit.
CF14 (E.OUT) External control for turning output on/ off
Enables or disables output on/ off control using an external contact (p.94).
Display Description
0.0 0.0 No delay (factory default setting)
0.5 to 99.9 0.5 to 99.9 Output-off delay time, 0.5 s to 99.9 s
Display Description
OFF OFF Disabled (factory default setting)
ON ON Enabled
Display Description
OFF OFF Disabled (factory default setting)
ON ON Enabled
Display Description
LO LOW 0 V to 5 V (factory default setting)
HI HIGH 0 V to 10 V
Display Description
LO LOW 0 V to 5 V (factory default setting)
HI HIGH 0 V to 10 V
Display Description
OFF OFF Disabled (factory default setting)
ON ON Enabled