64 PWR-01
Basic Features CONFIG Settings
CF41 (USB) USB interface setting
Enables or disables the USB interface.
By setting this parameter to “OFF,” you can disable the USB interface function even when a
USB cable is connected.
This parameter is applied when you turn the POWER switch off and on.
CF42 (232) RS232C interface setting
Enables or disables the RS232C interface.
By setting this parameter to “OFF,” you can disable the RS232C interface function even when
a RS232C cable is connected.
This parameter is applied when you turn the POWER switch off and on.
CF43 (TRAC) SCPI communication error display
Sets whether to display communication errors.
CF44 (PARA) Starting master-slave parallel operation
Sets whether to use the PWR-01 as a master unit or slave unit in master-slave parallel oper-
ation (p.102).
If you want to use the PWR-01 as a master unit, set the total number of units. If you want to
use the PWR-01 as a slave unit, select "SLAV (
Slave)."
This parameter is applied when you turn the POWER switch off and on.
You can also set this parameter when the PWR-01 is being used as a slave unit.
Display Description
OFF OFF USB disabled
ON ON USB enabled (factory default setting).
Display Description
OFF OFF RS232C disabled
ON ON RS232C enabled (factory default setting).
Display Description
OFF OFF SCPI communication errors are not displayed (factory default set-
ting).
ON ON SCPI communication errors are displayed.
Display Description
SLAV Slave Use the PWR-01 as a slave unit.
1 to 3
1
1 Up to two units for 1200W models
1 to 3
1
Total number of units including the master unit (1: standalone
operation (factory default setting) to 3)