8
INFORMATION ABOUT OVERHAULING
EN 98
Fig 8.4
8.2.6 3
-cylinder camshaft housing check
T
he camshaft housings only contain the timing system
side bushing
Q
.
Use an internal dial gauge to measure the diameters of
housings
X - W - K - Z
.
Use an internal dial gauge to measure the diameters of
housings
X1 - W1 - K1 - Z1 (Fig. 8.5)
. According to the
values measured, calculate the clearance between the
housing and gudgeon, which is to observe the values in
Tab. 8.2a
.
The
MAX
value of wear allowed is
0.120 mm
Important
•
Tab. 8.3a details the dimensional values of new
components only.
Tab 8.3a Housing and camshaft gudgeon
dimensions.
REF.
0.040 - 0.085
0.060 - 0.105
0.060 - 0.105
0.060 - 0.105
F