8
INFORMATION ABOUT OVERHAULING
EN 98
Fig 8.4
8.2.6 3
-cylinder camshaft housing check
T
he camshaft housings only contain the timing system
side bushing
Q
.
Use an internal dial gauge to measure the diameters of
housings
X - W - K - Z
.
Use an internal dial gauge to measure the diameters of
housings
X1 - W1 - K1 - Z1 (Fig. 8.5)
. According to the
values measured, calculate the clearance between the
housing and gudgeon, which is to observe the values in
Tab. 8.2a
.
The
MAX
value of wear allowed is
0.120 mm
Important
Tab. 8.3a details the dimensional values of new
components only.
Tab 8.3a Housing and camshaft gudgeon
dimensions.
REF.
DIMENSIONS
(mm)
CLEARANCE
VALUE (mm)
X
44.000 - 44.025
0.040 - 0.085
X1
43.940 - 43.960
W
43.000 - 43.025
0.060 - 0.105
W1
42.920 - 42.940
K
42.000 - 42.025
0.060 - 0.105
K1
41.920 - 41.940
Z
36.000 - 36.025
0.060 - 0.105
Z1
35.920 - 35.940
F
ig 8.5