Operating Instructions
80 of 206
BA KR 6, 16 F, KR C4 12.10.07 en
7.4.2 Variant 1, mounting base with centering (resin cartridge)
Features:
-- For floor--mounted manipulators only.
-- Mounting of 3 bedplates, each with 2 chemical anchors.
-- Manipulator installed on the three bedplates.
Notice!
When using chemical anchors (resin --bonded anchors), only resin cartridges
and anchors (threaded rods) from the same manufacturer may be used.
No diamond tools or core drills may be used for drilling the anchor holes; for
preference, drilling tools supplied by the anchor manufacturer are to be used.
The manufacturer ’s instructions for the use of resin --bonded anchors must also
be observed.
The following resin cartridges are used for this process:
G Resin cartridge with mixer nozzle for up to seven anchor holes with commercially avail-
able caulking gun.
Only correctly mixed resin may be used. To ensure this, as much resin as necessary must
be rejected after start--up until the emerging resin is homogenous. The same applies to
breaks in work (processing time exceeded); if required, a new mixer nozzle must be used.
D Installation
(1) Lift the manipulator with fork lift truck or lifting tackle.
(2) Fasten each of the three bedplates (Fig. 55/2) to the manipulator (3) by means of one
M20x55--8.8--A2K ISO 4017 hexagon bolt (1) and conical spring washer . Insert the
hexagon bolt (1) and conical spring washer and tighten it with a torque wrench in diago-
nally opposite sequence, increasing the tightening torque M
A
to the specified value in
several stages (M
A
= 370 Nm).
T wo bedplates are fitted with locating pins (4) for centering.