2NM/2NX/2NY/2NZ/2P0/2P6
1-4-41
7810 Short-circuited tempera-
ture sensor wire
Input from temperature sensor
is 31 or less continuously for 5
s.
Temperature
sensor
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Temperature sensor and control PWB
(YC30)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the key right PWB.
Control PWB 1. Check the control software and upgrade
to the latest, if necessary.
2. Replace the control PWB and check for
correct operation (see page 2-2-12).
7900 Drum EEPROM error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated 5 times
successively.
Mismatch of reading data from
2 locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
DR PWB
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DR PWB and drum connect PWB (YC1)
Drum connect PWB and connect left
PWB (YC3)
Connect left PWB and control PWB
(YC2)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the Drum unit (see page 1-5-
36).
Connect left PWB
Replace the connect left PWB (see page 2-
2-12).
Control PWB 1. Check the control software and upgrade
to the latest, if necessary.
2. Replace the control PWB and check for
correct operation (see page 2-2-12).
F000 Communication error
between Control PWB and
Operation PWB
Control PWB
1. Turn the main power swtch off and after
5 seconds, then turn power on.
2. Check that the wirings and connetors
between the control PWB and the
operation panel PWB are normal.
Operation PWB and control PWB
(YC2002)
3. Check that the DIMM memories in the
control PWB are well conducted and, if
not, replace.
4. Execute U021initialize memory. (see
page 1-3-22)
5. Replace the control PWB.
Operation PWB Replace the operation PWB (see page 2-2-
56).
Code Contents Related parts
Check procedures/
corrective measures

Table of Contents

Other manuals for Kyocera ECOSYS M3540dn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera ECOSYS M3540dn and is the answer not in the manual?

Kyocera ECOSYS M3540dn Specifications

General IconGeneral
Print TechnologyLaser
Print Resolution1200 x 1200 dpi
Duplex PrintingYes
Scan TypeColor CIS
Scan Resolution600 x 600 dpi
Fax CapabilityYes
Fax Transmission Speed33.6 kbps
Paper Capacity500 sheets
ConnectivityUSB, Ethernet
CopyingYes
ScanningYes
Modem Speed33.6 kbps
Standard Input Capacity500 sheets
Standard Output Capacity250 sheets
Maximum Output Capacity250 sheets
Maximum Print SizeA4
Standard InterfacesUSB 2.0, Ethernet
Ethernet LANYes
Internal Memory512 MB
Power Consumption (typical)661 W
DisplayLCD
FunctionsPrint, Copy, Scan, Fax
Operating System CompatibilityWindows, Mac OS, Linux
Print Speed40 ppm (pages per minute)
Copy Speed40 cpm (copies per minute)
Standard Paper Tray Media TypesRecycled
Maximum Internal Memory1, 536 MB
Weight22 kg
Product ColourBlack

Related product manuals