2PV/2PW
1-4-8
0180 Machine number mismatch
Machine number of main and
engine does not match.
Data damage of
EEPROM.
Contact the Service Administrative Division.
0600 Expanded memory (DIMM)
installing error
The expansion memory mod-
ules (DIMM) are not correctly
mounted.
Improper installa-
tion expanded
memory (DIMM).
Check the installation of the expanded mem-
ory (DIMM).
0610 Expanded memory (DIMM)
error
The expansion memory mod-
ules (DIMM) mounted on the
main PWB does not operate
correctly.
Defective
expanded memory
(DIMM).
Replace the expanded memory (DIMM) and
check for correct operation (see page 1-2-
12).
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation (see page 1-5-30).
0830 FAX control PWB flash pro-
gram area checksum error
A checksum error occurred
with the program of the FAX
control PWB.
Defective FAX soft-
ware.
Install the fax software.
Defective FAX con-
trol PWB.
Replace the FAX control PWB (see page 1-
5-36).
0840 Faults of RTC
The time is judged to go back
based on the comparison of
the RTC time and the current
time or five years or more
have passed.
The battery is dis-
connected from the
main PWB.
Check visually and remedy if necessary
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation (see page 1-5-30).
0870 FAX control PWB to main
PWB high capacity data
transfer error
High-capacity data transfer
between the FAX control PWB
and the main PWB of the
machine was not normally
performed even if the data
transfer was retried the speci-
fied times.
Improper installa-
tion FAX control
PWB.
Reinstall the FAX control PWB (see page 1-
5-36).
Defective FAX con-
trol PWB or main
PWB.
Replace the FAX control PWB or main PWB
and check for correct operation (see page 1-
5-36 or 1-5-30).
0920 Fax file system error
The backup data is not
retained for file system abnor-
mality of flash memory of the
FAX control PWB.
Defective FAX con-
trol PWB.
Replace the FAX control PWB and check for
correct operation (see page 1-5-36).
Code Contents Causes
Check procedures/