Page #187 background imageLoading...
Page #187 background image
2PV/2PW
1-4-51
(2-5) U010XX error code table: G3 transmission
Error code Description
U01000 An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001 Function of the unit differs from that indicated by a DIS signal.
U01016 An MCF signal was received but no DIS signal was received after transmission of an
EOM signal, and T1 timeout was detected.
U01019 No relevant signal was received after transmission of a CNC signal, and the preset num-
ber of command retransfers was exceeded (between units of our make).
U01020 No relevant signal was received after transmission of a CTC signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01021 No relevant signal was received after transmission of an EOR.Q signal, and the preset
number of command retransfers was exceeded (ECM).
U01022 No relevant signal was received after transmission of an RR signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01028 T5 time-out was detected during ECM transmission (ECM).
U01052 A DCN signal was received after transmission of an RR signal (ECM).
U01080 A PIP signal was received after transmission of a PPS.NULL signal.
U01092 During transmission in V.34 mode, communication was interrupted because of an impos-
sible combination of the symbol speed and communication speed.
U01093 A DCN or other inappropriate signal was received during phase B of transmission.
U01094 The preset number of command retransfers for DCS/NSS signals was exceeded during
phase B of transmission.
U01095 No relevant signal was received after transmission of a PPS (Q) signal during phase D of
transmission, and the preset number of command transfers was exceeded.
U01096 A DCN signal or invalid command was received during phase D of transmission.
U01097 The preset number of command retransfers was exceeded after transmission of an RR
signal or no response.

Table of Contents

Other manuals for Kyocera Ecosys M6526cdn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera Ecosys M6526cdn and is the answer not in the manual?

Kyocera Ecosys M6526cdn Specifications

General IconGeneral
Print TechnologyLaser
Copy Resolution600 x 600 dpi
Duplex PrintingYes
Paper Capacity250 sheets
FunctionsPrint, Copy, Scan, Fax
Fax Speed33.6 kbps
Mobile Printing SupportYes
Paper Output Capacity150 sheets
Max Paper SizeA4
Print Resolution1200 x 1200 dpi
Scan Resolution600 x 600 dpi
ConnectivityUSB 2.0, Ethernet
Warm-up Time29 seconds
Duty Cycle50, 000 pages per month
Recommended Monthly Print VolumeUp to 3, 000 pages
First Copy Out Time10 seconds
Zoom Range25% - 400%
Scan toEmail, FTP, SMB, USB
Fax Resolution300 x 300 dpi
Memory512 MB
Supported Paper SizesA4, A5, A6, B5, Letter, Legal