Provides contact information and operating hours for Labconco Corporation.
Describes the manual's content and how it applies to different Labconco biosafety cabinet models.
Details general safety warnings and precautions for operating the equipment.
Lists specific safety precautions relevant to the biosafety cabinet's operation.
Provides recommended practices for connecting the biosafety cabinet to an exhaust system.
Details the required airflow volumes and negative pressures for the exhaust system.
Instructions for changing biosafety cabinet configuration parameters in the field.
Procedure for adjusting the blower speed during initial or annual certification.
Instructions for adjusting the internal air damper to balance downflow and exhaust.
Steps to calibrate the airflow sensor for Type A2 and C1 biosafety cabinets.
Prepares for testing the supply HEPA filter on Type A2 biosafety cabinets.
Details the procedure for challenging and scanning the supply HEPA filter.
Describes how to test the exhaust HEPA filter on Type A2 biosafety cabinets.
Details the NSF/ANSI Standard 49 Primary Method for measuring inflow velocity.
Describes the Secondary Method for measuring inflow velocity when clearance is limited.
Instructions for resetting internal circuit breakers for power issues.
Information on the blower motor, including voltage checks and troubleshooting.
Troubleshooting steps for when the blower and lights are not operational.
Steps to diagnose why the blower fails to start.
Troubleshooting guide for when the unit's lights do not turn on.
Details on how to access and interpret Sash Sensor diagnostic data.
Provides information on accessing and interpreting Airflow Sensor diagnostic data.
Step-by-step guide for installing the Ventus canopy connection kit.
Instructions to reconfigure the biosafety cabinet after canopy installation.
Instructions for installing an airflow sensor on Type A2 without a Ventus Canopy.
Procedure to reconfigure the biosafety cabinet to enable a new airflow sensor.
Steps to calibrate a newly installed airflow sensor.
Instructions for installing the prefilter kit on Type A2 and B2 biosafety cabinets.
Lists consumable parts for Type A2 biosafety cabinets.
Lists consumable parts for Type B2 biosafety cabinets.
Lists consumable parts for Type C1 biosafety cabinets.