Clearing the Memory
If you have problems and cannot remedy the situation, you can clear
the memory and start over. Please use this only as a last remedy to
any problems.
The stations might have been programmed at the
factory. If you clear the memory you will lose all the
factory programming and have to start over assigning
numbers, dimmers, etc.
To clear the memory:
1: Press and hold the Menu/Cancel button for 10 seconds, until
LEVITON appears on the LCD display.
2: Immediately release the Menu/Cancel button.
3: Press and hold the Master Down button until the LCD
display shows INITIALIZING DEFAULTS.
Once
LEVITON
appears on the LCD display, the memory
is reset to the factory default values.