ProtoMat S64/S104
Troubleshooting
149/160
Description
Possible cause
Remedial measures
Error message:
Check whether the
tool is soiled or not
present.
Tool could not be
adjusted.
Check whether the tool is soiled/broken.
Error message: No
tool in collet.
No tool in the tool
holder.
Insert the tool into the tool holder.
Check if the tool position check (TPC) is
activated.
Autofocus very slow.
Insufficient PC
resources.
Use a suitable PC.
Probe pin of the tool
adjustment station is
ejected.
Air purge is set
incorrectly (too high).
Contact the LPKF Service.
Drilling tools do not
drill through the
material despite
correct material
settings.
Wrong offset value for
End Mill long.
Contact the LPKF Service.
Milling-depth
adjustment for conical
tools not possible
Tool is damaged.
Tool is worn.
Replace the tool.
Table 19: Fault table