214683 258 Revision A
Calibrating Reel Height Sensor (CLAAS 600 and 700 Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator’s manual for updates.
To calibrate reel height, follow these steps:
1. Place header off the ground 15–25 cm (6–10 in.).
Figure 3.450: CLAAS Combine Display,
Console, and Control Handle
2. Use control knob (A) to highlight the FRONT
ATTACHMENT icon (B) and press control knob (A) to
select it.
Figure 3.451: CLAAS Combine Display and
Console
3. Use control knob (A) to highlight the REEL icon (B), and
press control knob to select it.
OPERATION