Loading...
3-35
RT9150E OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
3
Published 2-23-2017, Control # 644-00
Grove
10
Telescope cylinder
location
Displayed telescopic section, e.g.
telescopic section 1:
On: Telescope cylinder is locked
here
Flashing: Next possibility for
locking telescope cylinder
Off: Telescope cylinder is in this
telescopic section, the distance to
the locking point is greater than 1 m
(3.3 ft)
or
Teleautomation on, symbol is
displayed
Teleautomation on/
off indicator
(1) Teleautomation on
(2) Teleautomation off (The section
number is displayed when
teleautomation is off).
Refer to Telescoping with
Teleautomation, page 3-135 for more
information.
11
Telescope section
display
Current relation of the telescopic
sections to each other (section of top
view).
Green: Locked
None: Unlocked or intermediate
position
Locking pins:
(1) On the telescopic section
(2) On the telescoping cylinder.
Refer to Description of Telescope
Section Views, page 3-36.
12
Teleautomation
direction indicator
(1) On: Start teleautomation with
extending.
(2) On: Start teleautomation with
retracting
Flashing: control lever movement not
correct.
13
Enter the value for
teleautomation
(1) Red: Teleautomation off
Yellow: Enter set value
Green: Teleautomation on
(2) Press button first time to turn input
on.
Press button (F9-F14) to set value
to next fixed length