3-41
RT9150E OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
Published 2-23-2017, Control # 644-00
7
Maximum/Current
swing angle
display
The display (3) indicates values for the
swing angle.
The display shows the following
values:
(4) Limit value, red
(5) Current value, blue
In case of manual input mode switched
on, the display (5) changes.
8
Enter objects
submenu
(1) Limitation by object display
(2) Point data display
(3) Current point data display
(4) Manual input on/off
(5) Select Previous point
(6) Select Next point
(7) Select angle/working radius
(8) Delete selected point data
(9) Delete all point data
Refer to Entering Points and Objects,
page 3-42.
9
Overall height
monitoring; on/off,
F9
Press the buttons for the required
monitoring functions once.
(1) Overall height
Dot is green: Monitoring switched on.
Dot is black: Monitoring switched off.
10
Working radius
monitoring; on/off,
F10
Press the buttons for the required
monitoring functions once.
(2) Working radius
Dot is green: Monitoring switched on.
Dot is black: Monitoring switched off.
11
Swing angle
monitoring; on/off,
F11
Press the buttons for the required
monitoring functions once.
(3) Swing angle
Dot is green: Monitoring switched on.
Dot is black: Monitoring switched off.
12
Object monitoring;
on/off, F12
Press the buttons for the required
monitoring functions once.
(4) Objects
Dot is green: Monitoring switched on.
Dot is black: Monitoring switched off.
13
Manual input on/
off
Press the button (1), the dot changes
color:
• Green: on
• Black: off.
Item Description Graphic Explanation
Reference Only