CONTROLLER MENUS: 1Y.6 CONTROL OPTIONS 7 - 45
D-MAXE with OI-B/OI-Nwww.maxcessintl.com MI 2-296 1 D
Prozessor bedienung.fm
Menu 1y.6.6 Hardlock
Note:
This parameter can only be used if an encoder is available for
the selected drive.
Description The
Hardlock
menu is used to set up three parameters. When
the operating mode switches to "Manual" the position of the
drive is kept active at that time by these three parameters.
Power is normally turned off to the drive in "Manual" mode. If
general conditions are unfavorable in the customer system, it
may happen that the drive is mis-adjusted while the power is
turned off. To prevent this from happening, the drive can be
kept active in "Manual" mode.
Menu
Key sequence for menu 1y.6.6:
Switch to the menus that describe the properties of the
Hardlock
parameter
Input
Menu
1y.6.6.1 Hardlock State
∙ Turn the
Hardlock
parameter on and off
Menu
1y.6.6.2 Hardlock Gain
∙ Set the gain for the
Hardlock
parameter
Menu
1y.6.6.3 Hardlock Polarity
Set the polarity for the
Hardlock
parameter