EasyManua.ls Logo

Maxcess D-MAXE - Parallel Input Matrix; Parallel Output Matrix

Maxcess D-MAXE
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL DATA 11 - 6
D-MAXE with OI-B/OI-Nwww.maxcessintl.com MI 2-296 1 D
TechnDaten.fm
Parallel input matrix Because of the option for customer-specific programming, there
may be some deviations in the parallel input matrix. Customer-
specific software adjustments of this type are described in the
"Supplementary Operating Instructions" for the D-MAXE system
and are included in the system documentation.
L = Low level (<= 0,9V or blank)
H = High level (3,6V - 24V)
Empty field = not relevant for the specific command
* Inputs 4 and 5 for moving the drive in "Manual" and "Servo
Center" modes
Offset of the guide point (RGPC) in "Automatic" mode
Parallel output matrix
The menu
Menu 1y.5.4 Digital Outputs, page7-42
can be used
to adjust the assignment of the logical state (1 or 0) to the
electrical state (active low, active high, high-impedance).
If there are differences compared to the table, they are
described in the "Supplementary Operating Instructions" in the
system documentation.
Mode
Inputs
543210
Locking, external -----H
Automatic - - L L H -
Manual - - L H L -
Servo-Center - - H L L -
Move drive left
*
LH----
Move drive right
*
HL----
RGPC left
*
LH----
RGPC right
*
HL----
RGPC RESET
*
HH----
Status
Outputs
B
*
A
*
LOSS OF NULL (Automatic mode) - 1
Drive Servo-Centered (Servo-Center
mode)
1-

Table of Contents

Related product manuals