TROUBLESHOOTING10 - 8
D-MAXE with OI-B/OI-N www.maxcessintl.comMI 2-296 1 D
Icon Status Indicates Possible error remedy
Information
Flashin
g
[0008] The web speed for web
speed-dependent
guiding is equal to 0.
However, if the web speed is not equal to 0,
check the signal for web speed.
and
[0300] The ASC function on the
selected drive has been
activated and triggered
and the motor is locked.
If locking was not intended, check the sensor
signal and ASC thresholds.
see
Menu 1y.9.1.1 Sensors, page 7-57
and
Menu 1y.3.y6 ASC, page 7-10
[0100] The motor is locked
because of an external
signal (e.g. PIOX,
fieldbus, application
control).
If you did not intend for the motor to be
locked, check the digital inputs. It is possible
that external locking is active
see
Menu 1y.9.1.3 Digital Inputs (X1), page 7-
57
If there is customer-specific programming,
refer to the
"Supplementary Operating
Instructions"
in the system documentation for
information about the X1 parallel interface.
or
[1000]
or
[2000]
The D-MAXE system is
expecting commands
from external devices.
The devices may not be connected to the
network.
Check whether these devices are correctly
connected to the network.