CONTROLLER MENUS: 1Y.3 JOB SETTINGS7 - 12
D-MAXE with OI-B/OI-N www.maxcessintl.comMI 2-296 1 D
Menu 1y.3.y7 Deadband
Description You can use the
Deadband
menu to define an area around the
guidepoint inside the sensor's field of view in which guiding is
not active in "Automatic" mode.
– If the web edge is in the deadband (1), no guiding will be
performed.
– If the web edge is in the area of the active field of view of the
sensor (2), guiding is performed.
Menu
Key sequence for menu 1y.3.y7:
The current setting for the
Deadband
parameter is shown here.
Enable the parameter for input
Input
Menu
1y.3.y7.1: Deadband
Standard value = 0%
A value of 0% means no active deadband is present.
A value of 100% means the sensor's entire field of view has been
defined as deadband. This would not be a useful setting.
Position the cursor under the digit whose value you want to
change
Change the value of the selected digit
Save the entry or cancel
1
2
1 - Deadband
2 - Active sensor field of view