Chapter 5 Parameters
74
resistance.
If internal brake resistance (P084=0) is used, this parameter is invalid.
P086 Power of external brake resistor
Range
Default
value
Unit Usage
1010000 60 W ALL
This parameter is set according to the actual power of the external brake resistor.
If internal brake resistance (P084=0) is used, this parameter is invalid.
P088 Encoder type
Range
Default
value
Unit Usage
0~31 0 ALL
Parameter meaning:
0: Automatic recognition.
1: Tamagawa.
2: Panasonic.
3: Nikon.
6: Decoding box
Note: when P088 is 2 (Panasonic), you need to select motor code by P002.
P090
Absolute position encoder type
(absolute only)
Range
Default
value
Unit Usage
02 0 ALL
Parameter meaning:
0: Single turn absolute value encoder.
1: Multi-turn absolute value encoder.
2: Absolute value encoders are used incrementally.
When the encoder does not have an external battery, the encoder cannot save multi-turn
information. Please set this parameter to 0.
P093 Enable fan alarm
Range
Default
value
Unit Usage
01 1 ALL
Parameter meaning:
0: Shielded fan fault alarm (except for special reasons, customers are not recommended
to shield this bit).
1: Allow fan failure alarm.
P094 Fan on temperature point
Range
Default
value
Unit Usage
25125 50 ALL
When the module temperature is higher than this temperature, the drive cooling fan
begins to operate.
When the module temperature falls below this temperature, the drive cooling fan stops