Chapter 5 Parameters
88
P315 User-defined PZD receiving word
Range
Default
value
Unit Usage
02 0 ALL
You can set this parameter to select the user-defined PZD content in the received packets.
Parameter meaning:
0: meaningless.
1: Additional torque (function to be improved);
2: Additional speed (functions to be improved).
P316 User-defined PZD sending word
Range
Default
value
Unit Usage
03 0 ALL
You can set this parameter to select user-defined PZD content in the sent packet.
Parameter meaning:
0: meaningless.
1: actual torque, unit %;
2: actual current, unit: 0.1a;
3: DI state, Bit0 ~ Bit4 said DI1 ~ DI5, respectively.
P320 Ramp acceleration time
Range
Default
value
Unit Usage
030000 1000 ms ALL
Sets the acceleration time of the motor from zero speed to rated speed.
If the command speed is lower than the rated speed, the acceleration time required is
correspondingly reduced.
This parameter has no effect in the application class AC4.
P321 Ramp deceleration time
Range
Default
value
Unit Usage
030000 1000 ms ALL
Sets the acceleration time of the motor from zero speed to rated speed.
If the command speed is lower than the rated speed, the acceleration time required is
correspondingly reduced.
This parameter has no effect in the application class AC4.
P322 Rapid deceleration time
Range
Default
value
Unit Usage
030000 100 ms ALL
Set deceleration time of motor from rated speed to zero speed.
If the current speed is lower than the rated speed, the deceleration time required is
correspondingly shortened.
This parameter is valid only during rapid deceleration.