5.4 Parameter description
89
P360
Maximum number of lost SOL
counts
Range
Default
value
Unit Usage
0~32767 5 ALL
In periodic synchronization mode, the SOL signals in each period are used to ensure data
reliability. If the SOL signals are continuously lost, you need to determine the validity of
the data. This parameter is used to set the maximum number of consecutive lost signals.
P362 Additional packet selection
Range
Default
value
Unit Usage
* 0 ALL
Select additional through this parameter, parameter changes, must be stored in the
EEPROM parameters, and drive power off, and then power on the operation, can take
effect!
P302 Packet Selection After this parameter is changed, the additional packet parameter is
reset. Therefore, you need to select this parameter again.
The packet type must be the same as that configured in the configuration.