Chapter 7 Troubleshooting
167
Print Head Nozzle Washing
If ejection failures (e.g., nozzle clogging or deflection) remain unresolved even after head cleaning (Head
Cleaning), apply nozzle wash to the print head.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station Maint.] > [Nozzle Wash], then press the [ENTER] key.
The carriage moves over the platen.
3
Open the maintenance cover on the right side.
"Wiper Cleaning"(P. 140)
4
Clean the cap rubber.
"Cap Rubber Cleaning"(P. 138)
5
Fill the cap with maintenance liquid.
Use a syringe to draw up some maintenance liquid and fill until it almost overflows from
the cap.
6
Close the maintenance covers.
7
Set the exposure time, then press the [ENTER] key.
Cleaning is performed automatically once print nozzle washing has ended.
If ejection failures (e.g., nozzle clogging or deflection) remain unresolved even after
washing the nozzles several times, contact your local dealer or our service office.
The heater temperature does not rise to the specified value.
This may indicate a problem with the setting.
Points to check Corrective action
Is the 100V/200V selector
switch set correctly?
Set the selector switch according to the power supply voltage. For the
switch position, contact our service office.
Is the heater temperature set? Set the heater temperature. "Setting the Heater Temperature"(P. 70)
"Media Setting Menu"(P. 114)